Proudly supplying Nilan systems to the UK for 16 years, the only UK supplier with direct contract with Nilan A/S and obligation to maintain the systems we supply
Screenshot 2024-11-28 at 13.04.09

The Official Supplier for Nuenta

Supplying Nilan systems to Nuenta in the UK

Nilan VPL 28 Heater

Many homeowners and small business operators seek energy-efficient solutions for heating and cooling their spaces, and the Nilan VPL 28 Heater stands out as a top choice. This innovative ventilation unit not only recovers heat but also offers a reversible cooling circuit, ensuring optimal air quality all year round. With intelligent humidity control and a user-friendly control unit, you can effortlessly enhance your indoor environment while saving on energy costs. Dive into this guide to explore how the Nilan VPL 28 can transform your heating and cooling experience.

Key Takeaways:

  • Energy Efficiency: The Nilan VPL 28 is designed for optimal energy efficiency, utilizing a heat pump for effective heat recovery and cooling.
  • Humidity Control: Equipped with intelligent humidity control, it adapts air exchange based on real-time humidity levels, ensuring efficient operation at all times.
  • Easy Integration: The unit can connect with the optional FU 28 heat pipe unit, enhancing heating efficiency during winter without the need for additional heating coils.
  • Advanced Communication: Features open Modbus RTU RS485 communication for seamless integration with external systems, allowing for monitoring and control.
  • User-Friendly Interface: Controlled via the CTS 602 touch panel, it offers customizable settings, weekly programming, and various operational controls.

Types of Nilan VPL 28 Heater Units

Before stepping into the specifics, it’s important to understand the variations of the Nilan VPL 28 units available to suit your ventilation needs:

  • Nilan VPL 28 – Core unit for heat recovery and cooling.
  • Standard Configuration – Basic setup for effective energy efficiency.
  • Optional FU 28 Heat Pipe Unit – Enhances winter performance.
  • Temperature Control Options – Integrated intelligent humidity control.
  • Communication Capabilities – Open Modbus for flexibility.

Recognizing the right variant is necessary in optimizing the energy recovery and comfort in your space.

Unit TypeFeatures
Nilan VPL 28Heat recovery, reversible cooling circuit
Standard ConfigurationBasic unit with necessary functionalities
Optional FU 28Increases heating efficiency in winter
Control UnitCTS 602 with touch interface
CommunicationModbus RTU for easy integration

Standard Configuration

Even in its standard configuration, the Nilan VPL 28 offers superior ventilation performance, capable of handling a ventilation requirement of up to 1000 m3/h, making it an ideal choice for homes and small commercial buildings.

Optional FU 28 Heat Pipe Unit

With the optional FU 28 heat pipe unit, the performance of the Nilan VPL 28 can be significantly enhanced, especially in winter conditions. This unit efficiently raises the temperature of the incoming outdoor air, increasing the overall efficiency of the heat pump.

Plus, by integrating the FU 28, you can often forgo the need for a heating coil and mixing circuit, streamlining your system while maintaining comfort. This feature utilizes advanced filtering options with ISO ePM10 and ISO ePM1 ratings, ensuring not only energy efficiency but also improved air quality in your environment.

Key Features of the Nilan VPL 28 Heater

Any home or small commercial building can benefit from the Nilan VPL 28, which comes equipped with several key features:

  • Energy-efficient heat recovery and cooling for up to 1000 m3/h.
  • Reversible cooling circuit for both heating and cooling air.
  • Fully tested and ready for use upon installation by authorized professionals.
  • Optional FU 28 heat pipe unit for enhanced winter efficiency.
  • Integrated intelligent humidity control via CTS 602 control unit.
  • Open Modbus RTU RS485 communication for easy monitoring and control.

Recognizing these features ensures your energy consumption remains low while maintaining a comfortable indoor climate.

Heat Recovery System

An energy-efficient heat recovery system is a standout feature of the Nilan VPL 28. Utilizing a heat pump, it effectively captures and repurposes energy, improving heating efficiency compared to traditional counterflow heat exchangers. This innovative design not only warms your indoor air during cold months but also cools it in warmer seasons.

Intelligent Humidity Control

While operating the Nilan VPL 28, you will appreciate the benefits of its intelligent humidity control system. The integrated CTS 602 control unit continuously monitors air humidity, adjusting the air exchange based on actual conditions rather than theoretical levels.

Humidity levels in your home can fluctuate significantly depending on factors such as occupancy and activities. The Nilan VPL 28’s advanced system takes this variability into account, ensuring optimal air quality and energy efficiency. By calculating the average humidity over 24 hours, it automatically adapts the ventilation, providing a tailored experience that supports your comfort while saving energy.

Installation Tips

Once again, when installing the Nilan VPL 28, careful consideration of a few key factors will help enhance its performance. Follow these vital tips:

  • Ensure proper ventilation pathways are clear.
  • Adhere to local electrical and plumbing regulations.
  • Opt for installation in a temperature-controlled environment.

Recognizing these factors will facilitate a more efficient operation of your system.

Proper Placement

With the Nilan VPL 28, proper placement is vital to maximize its heat recovery and cooling capabilities. Aim for a location that allows unobstructed airflow both to and from the unit, ensuring it functions efficiently throughout the year.

Authorised Professional Installation

To guarantee optimal performance, enlist an authorized professional for the installation of your Nilan VPL 28. This ensures that the unit is set up correctly and complies with all safety and operational guidelines.

This professional will also make certain that fitting and commissioning are executed with precision, adhering to the necessary specifications for the VPL 28, including the installation of the FU 28 heat pipe unit, if applicable. By having qualified personnel handle the installation, you can trust that your system will operate at its maximum efficiency and longevity.

Step-by-Step Operation Guide

Your journey with the Nilan VPL 28 heat pump begins with understanding its features and controls. For detailed instructions, refer to the comprehensive guide available on the Nilan VPL 28 heat pump. The following table highlights the imperative operational steps:

StepAction
1Ensure the unit is installed by an authorized technician.
2Familiarize yourself with the CTS 602 control panel.
3Set up your preferred operating modes.
4Monitor the air quality and adjust settings as needed.

Using the CTS 602 Control Panel

The CTS 602 control panel simplifies managing your Nilan VPL 28 unit. It offers a user-friendly interface where you can customize settings, monitor airflow, and adjust temperature controls. You can view real-time data on humidity and air quality, allowing for proactive adjustments to maintain optimal comfort in your space.

Adjusting Settings for Optimal Performance

While the Nilan VPL 28 is designed for efficiency, fine-tuning its settings ensures you get the best performance from the system. You can program specific operating times and fan speeds based on your daily routine.

Control the settings on the CTS 602 for enhanced energy savings and optimal indoor air quality. Adjust parameters such as weekly programming and fan speed according to usage patterns. Leveraging its advanced humidity control can lead to significant energy savings, as it adapts to the actual needs of your household throughout the changing seasons.

Factors to Consider

Many elements influence your decision when selecting the Nilan VPL 28 heater. Key considerations include:

  • Ventilation requirement up to 1000 m3/h
  • Energy efficiency of the heat recovery system
  • Installation by an authorized technician
  • Integration with the FU 28 heat pipe unit for enhanced efficiency
  • Intelligent humidity control features

Knowing these factors can help optimize your heating and cooling requirements.

Airflow Requirements

If your home or commercial space has specific airflow needs, the Nilan VPL 28 is designed to handle ventilation demands up to 1000 m3/h. Understanding your space’s airflow requirements is imperative for efficient heating and cooling.

Seasonal Adjustments

Seasonal changes can impact your heating and cooling preferences. The Nilan VPL 28 features intelligent control that adjusts to varying humidity levels, ensuring consistent performance throughout the year.

Factors such as outdoor temperature fluctuations and indoor humidity levels play a significant role in the efficiency of the Nilan VPL 28. By automating these seasonal adjustments, the unit can optimize energy usage during summer and winter months, catering to your comfort needs without compromising efficiency.

Pros and Cons

To evaluate the Nilan VPL 28 heater, consider its strengths and weaknesses compared to your specific needs.

Energy-efficient heat recovery Limited ventilation capacity (up to 1000 m3/h)Reversible cooling function Requires installation by certified professionalsIntelligent humidity control Dependency on electricity for operationAdvanced automation features Initial investment costs may be highOpen Modbus communication for integration Maintenance and filter replacement needed

Advantages of the Nilan VPL 28

Even with its compact design, the Nilan VPL 28 heater offers numerous advantages, including energy-efficient heat recovery through its advanced heat pump, which significantly enhances operational efficiency. The integration of intelligent humidity control ensures that your system adapts to fluctuations in indoor humidity levels, promoting energy savings without sacrificing comfort. With the added benefit of a reversible cooling function, this unit is a versatile solution for year-round climate control.

Potential Limitations

On the other hand, the Nilan VPL 28 does have certain potential limitations that you should consider. While the unit is designed for optimal performance, its maximum ventilation capacity may not suffice for larger spaces. Additionally, installation must be carried out by authorized professionals, incurring extra costs and logistics.

For instance, if you have a larger building, the 1000 m3/h ventilation limit may restrict your system’s effectiveness. Furthermore, since the unit relies on electricity, power outages or fluctuations can impact your heating and cooling capabilities. Also, be mindful of regular maintenance requirements, such as filter replacements, to ensure optimal performance over time. Considering these factors will help you make a more informed decision about the Nilan VPL 28 for your space.

Conclusion

So, if you are looking for an efficient and versatile solution for your heating and cooling needs, the Nilan VPL 28 is an excellent choice. With its innovative heat recovery system and intelligent humidity control, you can ensure optimal comfort in your home or small commercial space. Plus, its user-friendly CTS 602 control unit allows you to easily monitor and adjust settings to suit your preferences, making your environment more energy-efficient and comfortable year-round.

Nilan VPL 28 Heater FAQs

Q: What is the Nilan VPL 28 and how does it function?

A: The Nilan VPL 28 is an energy-efficient ventilation unit designed for heat recovery and cooling in homes and small commercial buildings with ventilation needs of up to 1000 m3/h. It utilises a heat pump that is more effective than traditional counterflow heat exchangers for heat recovery, allowing both heating and cooling of air through its reversible cooling circuit. It is supplied fully tested and ready for installation, which must be conducted by authorised professionals.

Q: What is the purpose of the FU 28 heat pipe unit, and how does it enhance the VPL 28’s performance?

A: The FU 28 heat pipe unit is an optional component connected to the VPL 28. It slightly raises the temperature of incoming outdoor air, enhancing the efficiency of the heat pump during winter. Typically, with the FU 28, there is no need for an additional heating coil with a mixing circuit. It also comes with specific filter options that improve air quality by capturing fine particles.

Q: How does the intelligent humidity control feature of the Nilan VPL 28 work?

A: The intelligent humidity control is managed by the CTS 602 control unit, which continuously adjusts air exchange based on real-time humidity conditions in the building. Rather than using a fixed humidity level, the integrated sensor calculates a 24-hour average to optimize air exchange rates. This dynamic adjustment allows the unit to operate more efficiently by adapting to varying occupancy and seasonal demands.

Q: What communication capabilities does the Nilan VPL 28 offer for remote monitoring and management?

A: The VPL 28 features an open Modbus RTU RS485 communication capability, allowing easy integration with external systems for monitoring and control. Users can connect multiple units to a computer for comprehensive management. The Modbus communication protocol is configurable, enabling adjustments to the address settings between 1 and 247 to suit specific requirements.

Q: What functionalities does the CTS 602 control panel provide for operating the Nilan VPL 28?

A: The CTS 602 HMI touch panel controls various functions of the VPL 28, including menu-driven operation, weekly programming, filter monitoring, fan speed adjustments, summer bypass for free cooling, and error notifications. The panel arrives with factory settings that can be customised based on operational needs, and users can choose between two front-page designs for ease of use. Detailed operating instructions are provided in a separate user manual included with the unit.